Table 4-58. RFCSEL9 Register Field Descriptions (continued)
Bit
Field
6-0
EV
SWCU117C – February 2015 – Revised September 2015
Submit Documentation Feedback
Type
Reset
Description
R/W
2h
Read/write selection value
0h = Always inactive
1h = AON programmable event 0. Event selected by AON_EVENT
MCU event selector,
AON_EVENT:EVTOMCUSEL.AON_PROG0_EV
2h = AON programmable event 1. Event selected by AON_EVENT
MCU event selector,
AON_EVENT:EVTOMCUSEL.AON_PROG1_EV
8h = Interrupt event from I2S
Ah = AUX Software event 0, AUX_EVCTL:SWEVSET.SWEV0
18h = Watchdog interrupt event, controlled by WDT:CTL.INTEN
22h = SSI0 combined interrupt, interrupt flags are found here
SSI0:MIS
23h = SSI0 combined interrupt, interrupt flags are found here
SSI1:MIS
24h = UART0 combined interrupt, interrupt flags are found here
UART0:MIS
27h = Combined DMA done, corresponding flags are here
UDMA0:REQDONE
5Dh = CRYPTO result available interrupt event, the corresponding
flag is found here CRYPTO:IRQSTAT.RESULT_AVAIL. Controlled
by CRYPTO:IRQSTAT.RESULT_AVAIL
64h = Software event 0, triggered by SWEV.SWEV0
65h = Software event 1, triggered by SWEV.SWEV1
69h = AON wake-up event, corresponds flags are here
AUX_EVCTL:EVTOMCUFLAGS.AON_WU_EV
6Ah = AUX Compare A event, corresponds to
AUX_EVCTL:EVTOMCUFLAGS.AUX_COMPA
6Bh = AUX Compare B event, corresponds to
AUX_EVCTL:EVTOMCUFLAGS.AUX_COMPB
6Ch = AUX TDC measurement done event, corresponds to the flag
AUX_EVCTL:EVTOMCUFLAGS.TDC_DONE and the AUX_TDC
status AUX_TDC:STAT.DONE
6Dh = AUX timer 0 event, corresponds to
AUX_EVCTL:EVTOMCUFLAGS.TIMER0_EV
6Eh = AUX timer 1 event, corresponds to
AUX_EVCTL:EVTOMCUFLAGS.TIMER1_EV
6Fh = Auto-take event from AUX semaphore, configured by
AUX_SMPH:AUTOTAKE
70h = AUX ADC done, corresponds to
AUX_EVCTL:EVTOMCUFLAGS.ADC_DONE
71h = AUX ADC FIFO watermark event, corresponds to
AUX_EVCTL:EVTOMCUFLAGS.ADC_FIFO_ALMOST_FULL
72h = Loopback of OBSMUX0 through AUX, corresponds to
AUX_EVCTL:EVTOMCUFLAGS.OBSMUX0
73h = AUX ADC interrupt event, corresponds to
AUX_EVCTL:EVTOMCUFLAGS.ADC_IRQ. Status flags are found
here AUX_EVCTL:EVTOMCUFLAGS
79h = Always asserted
Copyright © 2015, Texas Instruments Incorporated
Interrupts and Events Registers
Interrupts and Events
317