Download Print this page

Texas Instruments SimpleLink CC2620 Technical Reference Manual page 135

Zigbee rf4ce wireless mcu simplelink cc13 series; simplelink cc26 series

Advertisement

www.ti.com
2.7.4.6
STCR Register (Offset = 1Ch) [reset = C0075300h]
STCR is shown in
SysTick Calibration Value
Used to enable software to scale to any required speed using divide and multiply.
31
30
NOREF
SKEW
R-1h
R-1h
23
22
15
14
7
6
Bit
Field
31
NOREF
30
SKEW
29-24
RESERVED
23-0
TENMS
SWCU117C – February 2015 – Revised September 2015
Submit Documentation Feedback
Figure 2-76
and described in
Figure 2-76. STCR Register
29
28
21
20
13
12
5
4
Table 2-102. STCR Register Field Descriptions
Type
Reset
R
1h
R
1h
R
0h
R
75300h
Copyright © 2015, Texas Instruments Incorporated
Table
2-102.
27
26
RESERVED
R-0h
19
18
TENMS
R-75300h
11
10
TENMS
R-75300h
3
2
TENMS
R-75300h
Description
Reads as one. Indicates that no separate reference clock is
provided.
Reads as one. The calibration value is not exactly 10ms because of
clock frequency. This could affect its suitability as a software real
time clock.
Software must not rely on the value of a reserved. Writing any other
value than the reset value may result in undefined behavior.
An optional Reload value to be used for 10ms (100Hz) timing,
subject to system clock skew errors. The value read is valid only
when core clock is at 48MHz.
Cortex-M3 Processor Registers
25
24
17
16
9
8
1
0
135