Download Print this page

Texas Instruments SimpleLink CC2620 Technical Reference Manual page 748

Zigbee rf4ce wireless mcu simplelink cc13 series; simplelink cc26 series

Advertisement

Factory Configuration (FCFG)
9.2.1.29 FLASH_C_E_P_R Register (Offset = 174h) [reset = A0A2000h]
FLASH_C_E_P_R is shown in
Flash Compaction, Execute, Program and Read
31
30
29
28
15
14
13
12
A_EXEZ_SETUP
R-2h
Bit
Field
31-24
RVSU
23-16
PV_ACCESS
15-12
A_EXEZ_SETUP
11-0
CVSU
748
Device Configuration
Figure 9-51
and described in
Figure 9-51. FLASH_C_E_P_R Register
27
26
25
RVSU
R-Ah
11
10
9
Table 9-53. FLASH_C_E_P_R Register Field Descriptions
Type
Reset
R
Ah
R
Ah
R
2h
R
0h
Copyright © 2015, Texas Instruments Incorporated
Table
9-53.
24
23
22
21
8
7
6
5
CVSU
R-0h
Description
Repeat verify setup time in cycles. Used for repeated verifies during
program and erase. Value will be written to
FLASH:FSM_EX_VAL.REP_VSU by the flash device driver when an
erase/program operation is initiated.
Program verify EXECUTEZ->data valid time in half-microseconds.
Value will be converted to number of FCLK cycles by by flash device
driver and the converted value is written to
FLASH:FSM_EX_VAL.EXE_VALD when an erase/program
operation is initiated..
Address->EXECUTEZ setup time in cycles. Value will be written to
FLASH:FSM_CMP_VSU.ADD_EXZ by the flash device driver when
an erase/program operation is initiated..
Compaction verify setup time in cycles.
SWCU117C – February 2015 – Revised September 2015
www.ti.com
20
19
18
17
PV_ACCESS
R-Ah
4
3
2
1
Submit Documentation Feedback
16
0