Download Print this page

Texas Instruments SimpleLink CC2620 Technical Reference Manual page 706

Zigbee rf4ce wireless mcu simplelink cc13 series; simplelink cc26 series

Advertisement

Customer Configuration (CCFG)
9.1.1.16 CCFG_TAP_DAP_0 Register (Offset = FE4h) [reset = FFC5C5C5h]
CCFG_TAP_DAP_0 is shown in
Test Access Points Enable 0
31
30
29
28
RESERVED
R/W-FFh
15
14
13
12
PRCM_TAP_ENABLE
R/W-C5h
Bit
Field
31-24
RESERVED
23-16
CPU_DAP_ENABLE
15-8
PRCM_TAP_ENABLE
7-0
TEST_TAP_ENABLE
706
Device Configuration
Figure 9-16
and described in
Figure 9-16. CCFG_TAP_DAP_0 Register
27
26
25
24
11
10
9
8
Table 9-17. CCFG_TAP_DAP_0 Register Field Descriptions
Type
Reset
R/W
FFh
R/W
C5h
R/W
C5h
R/W
C5h
Copyright © 2015, Texas Instruments Incorporated
Table
9-17.
23
22
21
20
CPU_DAP_ENABLE
R/W-C5h
7
6
5
4
TEST_TAP_ENABLE
R/W-C5h
Description
Software must not rely on the value of a reserved. Writing any other
value than the reset value may result in undefined behavior.
Enable CPU DAP.
0xC5: Main CPU DAP access is enabled during power-up/system-
reset by ROM boot FW.
Any other value: Main CPU DAP access will remain disabled out of
power-up/system-reset.
Enable PRCM TAP.
0xC5: PRCM TAP access is enabled during power-up/system-reset
by ROM boot FW if enabled by corresponding configuration value in
FCFG1 defined by TI.
Any other value: PRCM TAP access will remain disabled out of
power-up/system-reset.
Enable Test TAP.
0xC5: TEST TAP access is enabled during power-up/system-reset
by ROM boot FW if enabled by corresponding configuration value in
FCFG1 defined by TI.
Any other value: TEST TAP access will remain disabled out of
power-up/system-reset.
SWCU117C – February 2015 – Revised September 2015
www.ti.com
19
18
17
16
3
2
1
0
Submit Documentation Feedback

Hide quick links:

Advertisement

loading