Interrupts and Events Registers
4.7.2.8
CPUIRQSEL7 Register (Offset = 1Ch) [reset = 22h]
CPUIRQSEL7 is shown in
Output Selection for CPU Interrupt 7
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
Bit
Field
31-7
RESERVED
6-0
EV
280
Interrupts and Events
Figure 4-17
and described in
Figure 4-17. CPUIRQSEL7 Register
RESERVED
R-0h
Table 4-22. CPUIRQSEL7 Register Field Descriptions
Type
Reset
R
0h
R
22h
Copyright © 2015, Texas Instruments Incorporated
Table
4-22.
9
Description
Software must not rely on the value of a reserved. Writing any other
value than the reset value may result in undefined behavior.
Read only selection value
22h = SSI0 combined interrupt, interrupt flags are found here
SSI0:MIS
SWCU117C – February 2015 – Revised September 2015