Download Print this page

Texas Instruments SimpleLink CC2620 Technical Reference Manual page 756

Zigbee rf4ce wireless mcu simplelink cc13 series; simplelink cc26 series

Advertisement

Factory Configuration (FCFG)
9.2.1.37 FLASH_VHV_PV Register (Offset = 194h) [reset = X]
FLASH_VHV_PV is shown in
Flash VHV Program Verify
31
30
29
28
RESERVED
R-0h
15
14
13
12
VCG2P5
Bit
Field
31-28
RESERVED
27-24
TRIM13_PV
23-20
RESERVED
19-16
VHV_PV
15-8
VCG2P5
7-0
VINH
756
Device Configuration
Figure 9-59
and described in
Figure 9-59. FLASH_VHV_PV Register
27
26
25
TRIM13_PV
R-X
11
10
9
R-X
Table 9-61. FLASH_VHV_PV Register Field Descriptions
Type
Reset
R
0h
R
X
R
0h
R
8h
R
X
R
1h
Copyright © 2015, Texas Instruments Incorporated
Table
9-61.
24
23
22
21
RESERVED
R-0h
8
7
6
5
Description
Software must not rely on the value of a reserved. Writing any other
value than the reset value may result in undefined behavior.
Value will be written to FLASH:FVHVCT1.TRIM13_PV by the flash
device driver when an erase/program operation is initiated.
Default value holds trim value from production test.
Software must not rely on the value of a reserved. Writing any other
value than the reset value may result in undefined behavior.
Value will be written to FLASH:FVHVCT1.VHVCT_PV by the flash
device driver when an erase/program operation is initiated.
Control gate voltage during read, read margin, and erase verify.
Value will be written to FLASH:FVNVCT.VCG2P5CT by the flash
device driver when an erase/program operation is initiated.
Default value holds trim value from production test.
Inhibit voltage applied to unselected columns during programming.
SWCU117C – February 2015 – Revised September 2015
www.ti.com
20
19
18
17
VHV_PV
R-8h
4
3
2
1
VINH
R-1h
Submit Documentation Feedback
16
0

Hide quick links:

Advertisement