10.1.6.3.3 CBC-MAC
For CBC-MAC operations, the following configuration parameters are required:
Key from the key store module
IV must be written with zeroes
Control register settings (mode, direction, key size)
Length of the authenticated data (may be nonblock size aligned)
The input data can end misaligned for CBC-MAC operations. If this is the case, the crypto core internally
pads the last input data block.
The length field can have any value. If a data stream is finished and the next data stream uses the same
key and control, writing only a part of the next context is not allowed. A new data stream must always
write the complete context. The length field must never be written with zeroes.
SWCU117C – February 2015 – Revised September 2015
Submit Documentation Feedback
Copyright © 2015, Texas Instruments Incorporated
AES Cryptoprocessor Overview