Download Print this page

Texas Instruments SimpleLink CC2620 Technical Reference Manual page 405

Zigbee rf4ce wireless mcu simplelink cc13 series; simplelink cc26 series

Advertisement

www.ti.com
Bit
23–0
5.3.4.1.2 ICEPick Control Register
Bit
Field
23–7
Reserved
6
BlockSysReset
5–1
Reserved
0
SystemReset
5.3.4.1.3 Linking Mode Register
Bit
Field
23–4
Reserved
3–1
TAPLinkMode
0
ActivateMode
Value
000
011
001–010, 100–111
SWCU117C – February 2015 – Revised September 2015
Submit Documentation Feedback
Table 5-14. All0s Register
Field
Width
Zero
24
Table 5-15. ICEPick Control Register
Width
Type
17
R/W
1
R/W
5
R/W
1
R/W
Table 5-16. ICEPick Linking Mode Register
Width
Type
20
R/W
3
R/W
1
R/W
Table 5-17. ICEPick TAP Link Mode
Mode
Behavior
Always-first
ICEPick TAP always exists and is linked as the TAP closest to TDI.
When activated, the ICEPick TAP is no longer visible between the device
Disappear-forever
TDI and TDO. Only a power-on reset makes the TAP visible again.
Reserved
Reserved
Copyright © 2015, Texas Instruments Incorporated
Type
Reset
R
0
Reset
Description
0
Reserved
0
When 1, the device system reset signal is blocked.
0
Reserved
Emulator controlled System Reset
This signal provides the scan controller with the ability to
assert the system warm reset. When a 1 is written, this
behaves as if the external chip warm reset signal had
0
been momentarily asserted. This signal does not reset
any emulation logic. This is a self-clearing bit. This is
cleared by the assertion of the reset requested.
Writing a 0 has no effect.
Reset
Description
0x0
Reserved
0
See
Table 5-17
0
When a 1 is written to this bit, the currently selected
TAPLinkMode is activated. ICEPick links the TAPs
according to these settings when the ICEPick TAP is
advanced to Run‑Test-Idle with any opcode in the IR.
ICEPick
Description
Read zero
JTAG Interface
405

Hide quick links:

Advertisement

loading