ip pim graceful-restart

This feature permits configuration of non-stop forwarding (NSF or graceful restart) capability of a PIM router to its
neighbors.
E-Series
Syntax
[ipv6] ip pim graceful-restart {helper-only | nsf [restart-time
| stale-entry-time]}
Parameters
ipv6
helper-only
nsf
restart-time
stale-entry-time
Defaults
as above
Command Modes
CONFIGURATION
Command History
Version 8.2.1.0
Version 7.6.1.0
Usage
When an NSF-capable router comes up, it announces the graceful restart capability and
Information
restart duration as a Hello option. The receiving router notes the Hello option. Routers not
NSF-capable discard the unknown Hello option and adjacency is not affected.
When an NSF-capable router goes down, the neighboring PIM speaker preserves the states
and continues the forwarding of multicast traffic while the neighbor router restarts.

ip pim join-filter

Permit or deny PIM Join/Prune messages on an interface using an extended IP access list. This command prevents the
PIM-SM router from creating state based on multicast source and/or group.
C-Series, E-Series, S-Series, Z-Series, S4810
Syntax
ip pim join-filter ext-access-list {in | out}
Enter the keyword ipv6 to enable graceful-restart for the IPv6
multicast routes.
Enter the keywords helper-only to configure as a receiver
(helper) only by preserving the PIM status of a graceful restart PIM
neighboring router.
Enter the keyword nsf to configure the non-stop forwarding
capability.
(OPTIONAL) Enter the keywords restart-time followed by the
number of seconds estimated for the PIM speaker to restart. The
range is 30 to 300 seconds. The default is 180 seconds.
(OPTIONAL) Enter the keywords stale-entry-time followed by
the number of seconds for which entries are kept alive after restart.
The range is 30 to 300 seconds. The default is 60 seconds.
Introduced on the E-Series ExaScale. Added the ipv6 option for the
E-Series.
Introduced on the E-Series.