are learned by different routing protocols and for cases where the destination is reachable
over ECMP.
Related
sflow extended-gateway enable
Commands
sflow extended-router enable
show sflow

sflow polling-interval (Global)

Set the sFlow polling interval at a global level.
C-Series, E-Series, S-Series, Z-Series, S4810
Syntax
sflow polling-interval interval value
To return to the default, use the no sflow polling-interval interval command.
Parameters
interval value
Defaults
20 seconds
Command Modes
CONFIGURATION
Command History
Version 8.3.11.1
Version 8.3.7.0
Version 8.2.1.0
Version 8.1.1.0
Version 7.7.1.0
Version 7.6.1.0
Version 7.4.1.0
Usage
The polling interval for an interface is the maximum number of seconds between successive
Information
samples of counters to be sent to the collector. This command changes the global default
counter polling (20 seconds) interval. You can configure an interface to use a different polling
interval.
Related
sflow polling-interval (Interface)
Commands
– enables packing information on an extended gateway.
– enables packing information on a router.
– displays the sFlow configuration.
Enter the interval value in seconds. The range is 15 to 86400 seconds.
The default is 20 seconds.
Introduced on the Z9000.
Introduced on the S4810.
Introduced on S-Series Stacking.
Introduced on the E-Series ExaScale.
Introduced on the S-Series.
Introduced on the C-Series.
Introduced on the E-Series.
– sets the polling interval for an interface.