redundancy force-failover stack-unit
Force the standby unit in the stack to become the management unit.
S-Series
Syntax
redundancy force-failover stack-unit
Defaults
Not enabled.
Command Modes
EXEC Privilege
reset stack-unit
Reset any designated stack member except the management unit (master unit).
S-Series
Syntax
reset stack-unit 0-11 hard
Parameters
0-11
hard
Defaults
none
Command Modes
EXEC
Command History
Version 8.3.1.0
Version 7.8.1.0
Version 7.7.1.0
Usage
Resetting the management unit is not allowed, and an error message displays if you try to do
Information
so. Resetting is a soft reboot, including flushing the forwarding tables.
Starting with FTOS version 7.8.1.0, you can run this command directly on the stack standby unit
(standby master) to reset the standby. You cannot reset any other unit from the standby unit.
Example
Stack MAC : 00:01:e8:8b:1a:36
Reload-Type : normal-reload [Next boot : normal-reload]
-- Stack Info --
Unit UnitType Status
----------------------------------------------------
0
1
2
3
4
5
1520
Enter the stack member unit identifier of the stack member to reset.
Reset the stack unit if the unit is in a problem state.
Added the hard reset option.
Augmented to run on the standby unit in order to reset the standby
unit directly.
Introduced on the S-Series.
Management online S4810
Standby
online S4810
Member
online S4810
Member
online S4810
Member
online S4810
Member
online S4810
ReqTyp CurTyp Version Ports
S4810 8-3-12-1 64
S4810 8-3-12-1 64
S4810 8-3-12-1 64
S4810 8-3-12-1 64
S4810 8-3-12-1 64
S4810 8-3-12-1 64