Show Iscsi Session Detailed - Dell Force10 S4810P Reference Manual

Ftos command line reference guide for the s4810 system ftos 9.1.(0.0)
Hide thumbs Also See for Force10 S4810P:
Table of Contents

Advertisement

Version 8.3.16.0
Example
FTOS# show isci session
Session 0:
------------------------------------------------------
Target: iqn.2001-05.com.equallogic:
0-8a0906-0e70c2002-10a0018426a48c94-iom010
Initiator: iqn.1991-05.com.microsoft:win-x9l8v27yajg
ISID: 400001370000
Session 1:
---------------------------------------------------------
Target: iqn.2001-05.com.equallogic:
0-8a0906-0f60c2002-0360018428d48c94-iom011
Initiator: iqn.1991-05.com.microsoft:win-x9l8v27yajg
ISID: 400001370000.
Usage
Only sessions observed by the switch will be learnt; sessions flowing through an adjacent
Information
switch will not be learnt.
After the switch is reloaded, any information exchanged during the initial handshake is not
available. If the switch picks up the communication after reloading, it would detect a session
was in progress but could not obtain complete information for it. Any incomplete information of
this type would not be available in the "show" commands.
Related
Commands

show iscsi session detailed

Display detailed information on active iSCSI sessions on the switch.
S4810
Syntax
show iscsi session detailed [session isid]
Parameters
isid
Command Modes
Command History
Version 8.3.12.0
Version 8.3.16.0
964
Introduced on MXL 10/40GbE Switch IO Module.
show iscsi
– displays the currently configured iSCSI settings.
show iscsi session detailed
on the switch.
show run iscsi
– shows run iscsi.
Enter the session's iSCSi ID to display detailed information about the
specified iSCSi session.
EXEC
EXEC Privilege
Introduced on the S4810.
Introduced on MXL 10/40GbE Switch IO Module.
– displays detailed information about active iSCSI sessions

Advertisement

Table of Contents
loading

Table of Contents