Usage
This command changes the sampling rate for an Interface. By default, the sampling rate of an
Information
interface is set to the same value as the current global default sampling rate. If the value
entered is not a correct power of 2, the command generates an error message with the
previous and next power-of-2 value. Select one of these two number and re-enter the
command.
Related
sflow sample-rate (Global)
Commands
show sflow
Display the current sFlow configuration.
C-Series, E-Series, S-Series, Z-Series, S4810
Syntax
show sflow [interface]
Parameters
interface
Command Modes
Command History
Version 8.3.11.1
Version 8.3.7.0
Version 8.2.1.0
1476
Introduced on the E-Series ExaScale.
Introduced on the S-Series.
Introduced on the C-Series.
Introduced on the E-Series.
– changes the sampling rate globally.
(OPTIONAL) Enter the following keywords and slot/port or number
information:
•
•
•
•
•
•
EXEC
•
EXEC Privilege
Introduced on the Z9000.
Introduced on the S4810.
Introduced on S-Series Stacking.
For an 100/1000 Ethernet interface, enter the keyword
GigabitEthernet followed by the slot/port information.
For a 1-Gigabit Ethernet interface, enter the keyword
GigabitEthernet followed by the slot/port information.
For a Loopback interface, enter the keyword loopback
followed by a number from 0 to 16383.
For a SONET interface, enter the keyword sonet followed by
the slot/port information.
For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet followed by the slot/port
information.