Stacking; Redundancy Disable-Auto-Reboot - Dell Force10 S4810P Reference Manual

Ftos command line reference guide for the s4810 system ftos 9.1.(0.0)
Hide thumbs Also See for Force10 S4810P:
Table of Contents

Advertisement

Stacking

All commands in this chapter are specific to the Dell Force10 operating software (FTOS) on the S-Series and S4810
platforms.
The commands are always available and operational, whether or not the S-Series has a stacking module inserted. You
can use the commands to pre-configure a switch, so that the configuration settings are invoked when the switch is
attached to other S-Series units.
For information about using the S-Series stacking feature, refer to the "Stacking S-Series Switches" chapter in the
Configuration Guide .
CAUTION: You cannot enable S4810 stacking simultaneously with virtual link trunking (VLT). If you enable both at
the same time, unexpected behavior occurs.

redundancy disable-auto-reboot

Prevent the S-Series stack management unit, stack member unit, and standby unit from rebooting if they fail.
S-Series
Syntax
redundancy disable-auto-reboot [members | 0-11]
To return to the default, use the no redundancy disable-auto-reboot stack-
unit command.
Defaults
Disabled (the failed switch is automatically rebooted).
Command Modes
CONFIGURATION
Command History
Version 8.3.1.0
Version 7.7.1.0
Usage
The range is 0 to 11. Enabling this command keeps the failed switch in the Failed state. The
Information
switch does not reboot until it is manually rebooted. When enabled, it is not displayed in the
running-config. When disabled, it is displayed in the running-config.
Related
show redundancy
Commands
Added the members option.
Introduced on the S-Series.
– displays the current redundancy status.
51
FTOS
1519

Advertisement

Table of Contents
loading

Table of Contents