Maintenance-Object Repair Procedures
Table 8-509. Test #884 Memory Checksum Test
Error
Test
Code
Result
Description / Recommendation
1006,
ABORT
Since the IPSI's Packet Interface circuit is out of service, normal maintenance
1137
tests do not run on the IPSI circuit pack.
1. Enter the reset packet-interface Uc command to reset the Packet
1334
ABORT
The Packet Interface command queue is full. This should be a temporary
condition caused by a high rate of commands being sent to a Packet Interface.
Continued operation with a full command queue would cause a system WARM
restart that may escalate to more severe restart levels.
1. Retry the command at 10-second intervals up to 5 times.
1335
ABORT
Internal IPSI error. The Packet Interface is on the standby IPSI, so this test is
not allowed to execute.
1. To run this test on the standby Packet Interface, enter set
2000
ABORT
Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
2500
ABORT
Internal system error
1. Retry the command.
NO
The IPSI circuit pack's Packet Interface circuit is assigned, but is not detected
BOARD
as being physically present.
1. If the IPSI circuit pack is present, replace it.
2. If not, insert a TN2312AP IPSI circuit pack in the assigned slot, and run the
8-1256
Issue 1 May 2002
Interface circuit.
For further action, see the repair procedures in
8-1256
for the Packet Interface Reset test (#889).
ipserver-interface Uc to activate it.
test again.
Table 8-509 on page
Continued on next page