Download Print this page

Renesas M16C/50 Series User Manual page 345

Advertisement

M16C/5L Group, M16C/56 Group
17.2
Registers
Refer to "registers and settings" in each mode for register and bit settings.
Three-phase motor control timer function uses timers A1, A2, A4, and B2. For other registers related to
timers A1, A2, A4, and B2, refer to 15. "Timer A" and 16. "Timer B".
Table 17.3
Registers
Address
01DAh
Three-Phase Protect Control Register
0302h
Timer A1-1 Register
0303h
0304h
Timer A2-1 Register
0305h
0306h
Timer A4-1 Register
0307h
0308h
Three-Phase PWM Control Register 0
0309h
Three-Phase PWM Control Register 1
030Ah
Three-Phase Output Buffer Register 0
030Bh
Three-Phase Output Buffer Register 1
030Ch
Dead Time Timer
Timer B2 Interrupt Generation Frequency Set
030Dh
Counter
030Eh
Position-Data-Retain Function Control Register
0318h
Port Function Control Register
0328h
Timer A1 Register
0329h
032Ah
Timer A2 Register
032Bh
032Eh
Timer A4 Register
032Fh
0334h
Timer B2 Register
0335h
033Eh
Timer B2 Special Mode Register
R01UH0127EJ0110 Rev.1.10
Sep 01, 2011
Register
17. Three-Phase Motor Control Timer Function
Symbol
TPRC
TA11
TA21
TA41
INVC0
INVC1
IDB0
IDB1
DTT
ICTB2
PDRF
PFCR
TA1
TA2
TA4
TB2
TB2SC
Reset Value
00h
XXh
XXh
XXh
XXh
XXh
XXh
00h
00h
XX11 1111b
XX11 1111b
XXh
XXh
XXXX 0000b
0011 1111b
XXh
XXh
XXh
XXh
XXh
XXh
XXh
XXh
X000 0000b
Page 308 of 803