7.4.3.2
Voltage Monitor 2 Interrupt and Voltage Monitor 2 Reset
Table 7.6 lists Procedure for Setting Voltage Monitor 2 Interrupt/Reset Related Bits.
Table 7.6
Procedure for Setting Voltage Monitor 2 Interrupt/Reset Related Bits
Step
Voltage Monitor 2
Interrupt
1
Set the CM14 bit in the CM1 register to 0 (125
kHz on-chip oscillator on)
2
Wait for digital filter sampling clock x 3 cycles.
3
Set the VW12E bit in the VWCE register to 1 (voltage detector enabled).
4
Use bits VD2LS3 to VD2LS0 in the VD2LS register to select Vdet2.
5
Set the VC27 bit in the VCR2 register to 1 (voltage detector 2 enabled).
6
Wait for td(E-A).
7
Use bits VW2F0 to VW2F1 in the VW2C
register to select the digital filter sampling
clock.
(2)
Set the VW2C1 bit in the VW2C register to 0
8
(digital filter enabled).
(2)
Set the VW2C6 bit in
9
the VW2C register to 0
(voltage monitor 2
interrupt mode).
10
Set the VW2C2 bit in the VW2C register to 0 (Vdet2 passage not detected).
11
Set the VW2C0 bit in the VW2C register to 1 (voltage monitor 2 interrupt/reset enabled).
Notes:
1.
Set the VW2C7 bit to 1 (when VCC reaches Vdet2 or below) for the voltage monitor 2 reset.
2.
When the VW2C0 bit is 0, steps 7, 8, and 9 can be executed simultaneously (with one instruction).
When using voltage monitor 2 interrupt or voltage monitor 2 reset to exit stop mode, set the VW2C1
bit in the VW2C register to 1 (digital filter disabled).
When voltage monitor 2 reset is generated, the LVD2R bit in the RSTFR register is automatically
becomes 1 (voltage monitor 2 reset detected). Refer to 6.4.5 "Voltage Monitor 2 Reset" for status
after reset.
Figure 7.6 shows Voltage Monitor 2 Interrupt/Reset Operation Example.
R01UH0127EJ0110 Rev.1.10
Sep 01, 2011
When Using the Digital Filter
Voltage Monitor 2
Reset
Set the VW2C6 bit in
the VW2C register to 1
(voltage monitor 2
reset mode).
When Not Using the Digital Filter
Voltage Monitor 2
Interrupt
(no wait time)
Use the VW2C7 bit in the VW2C register to
select the timing of the interrupt and reset
(1)
request.
Set the VW2C1 bit in the VW2C register to 1
(digital filter disabled).
Set the VW2C6 bit in
the VW2C register to 0
(voltage monitor 2
interrupt mode).
7. Voltage Detector
Voltage Monitor 2
Reset
Set the VW2C6 bit in
the VW2C register to 1
(voltage monitor 2
reset mode).
Page 87 of 803

Advertisement

loading