Download Print this page

Renesas M16C/50 Series User Manual page 319

Advertisement

M16C/5L Group, M16C/56 Group
16.2
Registers
Table 16.3 lists registers associated with timer B.
Set the TCDIV00 bit in the TCKDIVC0 register before setting other registers associated with timer B. After
changing the TCDIV00 bit, set other registers associated with timer B again.
Refer to "registers and the setting" in each mode for registers and bit settings.
Table 16.3
Registers
Address
0012h
Peripheral Clock Select Register
0015h
Clock Prescaler Reset Flag
01C0h
Timer B0-1 Register
01C1h
01C2h
Timer B1-1 Register
01C3h
01C4h
Timer B2-1 Register
01C5h
Pulse Period/Pulse Width Measurement
01C6h
Mode Function Select Register 1
01C8h
Timer B Count Source Select Register 0
01C9h
Timer B Count Source Select Register 1
01CBh
Timer AB Division Control Register 0
0320h
Count Start Flag
0330h
Timer B0 Register
0331h
0332h
Timer B1 Register
0333h
0334h
Timer B2 Register
0335h
033Bh
Timer B0 Mode Register
033Ch
Timer B1 Mode Register
033Dh
Timer B2 Mode Register
R01UH0127EJ0110 Rev.1.10
Sep 01, 2011
Register
Symbol
Reset Value
PCLKR
0000 0011b
CPSRF
0XXX XXXXb
TB01
TB11
TB21
PPWFS1
XXXX X000b
TBCS0
TBCS1
TCKDIVC0
0000 X000b
TABSR
TB0
TB1
TB2
TB0MR
00XX 0000b
TB1MR
00XX 0000b
TB2MR
00XX 0000b
16. Timer B
XXh
XXh
XXh
XXh
XXh
XXh
00h
X0h
00h
XXh
XXh
XXh
XXh
XXh
XXh
Page 282 of 803