Avaya S8700 Maintenance Manual page 1997

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

PMS-LINK (Property Management System Link)
m. The link was taken down by the switch because the threshold for
application protocol violations has been exceeded by the PMS. The
protocol never started and messages were received and/or messages
were received in a state in which they were not expected. (Refer to Error
Type 2817 for recommended strategy.)
n. Link was taken down by the switch because the threshold for link protocol
violations has been exceeded by the PMS. PMS is sending "garbage" to
the switch.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below. For example,
by clearing error codes associated with the Link Tear Down test (#213), you may
also clear errors generated from other tests in the testing sequence.
Order of Investigation
Link Tear Down test (#213)
Link Retry test (#215)
1.
D = Destructive; ND = Nondestructive
555-233-143
Short Test
Long Test
Sequence
Sequence
X
X
X
Issue 1 May 2002
1
D/ND
D
ND
8-1275