Avaya S8700 Maintenance Manual page 1990

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Table 8-514. Test #889 Reset Test
Error
Test
Code
Result
Description / Recommendation
1334
ABORT
The Packet Interface circuit's command queue is full. This should be a
temporary condition caused by a high rate of commands being sent to a Packet
Interface circuit. Continued operation with a full command queue would cause
a system WARM restart that could escalate to more severe restart levels.
1. Retry the command at 10 second intervals up to 5 times.
1335
ABORT
Internal IPSI error. The Packet Interface circuit is on the standby IPSI, and this
test is not allowed to execute.
1. If you wish to run this test on the standby Packet Interface, enter set
1362
ABORT
The Reset test is not allowed to run because the Packet Interface is in service.
Resetting an active IPSI circuit pack's Packet Interface while in service is not
allowed since this is a destructive test.
1. Use the status packet-interface command to determine the service state
2000
ABORT
Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
2500
ABORT
Internal system error
1. Retry the command.
NO
The IPSI circuit pack's Packet Interface is assigned but is not detected as being
BOARD
physically present.
1. If the IPSI circuit pack is present, replace it.
2. If not, insert a TN2312AP IPSI circuit pack in the assigned slot, and rerun
5001
ABORT
The TDM clock in the Processor port network has failed.
1. See
5002
ABORT
The packet bus in the Processor port network has failed.
1. See
Any
FAIL
The diagnostic tests failed for the IPSI's Packet Interface failed. If the system
is equipped with the
reset will run only on demand if the Packet Interface is on the standby IPSI
circuit pack or if Packet Interface is in an out-of-service state on the active IPSI.
1. Retry the command reset packet-interface.
2. If the reset fails, replace the circuit pack.
PASS
The IPSI's Packet Interface diagnostic software passed. The Packet Interface
is put back into service automatically.
8-1268
Issue 1 May 2002
ipserver-interface Uc to activate it.
of the Packet Interface circuit. If the circuit is out of service, try the Reset
command again.
the test.
''TDM-CLK (TDM Bus Clock)'' on page 8-1604
''PKT-BUS (Packet Bus)'' on page 8-1230
high-reliability or critical-reliability configuration
to clear this failure.
to clear this failure.
, the
Continued on next page
555-233-143

Advertisement

Table of Contents
loading

Table of Contents