Rtc Hours And Minutes Counter Register; Table 23-3 Rtc Days Counter Register Description; Table 23-4 Rtc Hours And Minutes Counter Register Description - Motorola DragonBall MC9328MX1 Reference Manual

Integrated portable system processor
Table of Contents

Advertisement

Name
Reserved
Reserved—These bits are reserved and should read 0.
Bits 31–9
DAYS
Day Setting—Indicates the current day count.
Bits 8–0

23.2.2 RTC Hours and Minutes Counter Register

The real-time clock hours and minutes counter register (HOURMIN) is used to program the hours and
minutes for the TOD clock. It can be read or written at any time. After a write, the time changes to the new
value. This register cannot be reset because the real-time clock is always enabled at reset.
HOURMIN
BIT
31
30
29
TYPE
r
r
r
0
0
0
RESET
BIT
15
14
13
TYPE
r
r
r
0
0
0
RESET
Table 23-4. RTC Hours and Minutes Counter Register Description
Name
Reserved
Reserved—These bits are reserved and should read 0.
Bits 31–13
HOURS
Hour Setting—Indicates the current hour.
Bits 12–8
Reserved
Reserved—These bits are reserved and should read 0.
Bits 7–6
MINUTES
Minute Setting—Indicates the current minute.
Bits 5–0
MOTOROLA
Table 23-3. RTC Days Counter Register Description
Description
RTC Hours and Minutes Counter
28
27
26
25
r
r
r
r
0
0
0
0
12
11
10
9
HOURS
rw
rw
rw
rw
?
?
?
?
Description
Real-Time Clock (RTC)
DAYS can be set to any value
between 0 and 511.
Register
24
23
22
21
r
r
r
r
0
0
0
0
0x0000
8
7
6
5
rw
r
r
rw
?
0
0
?
0x????
Programming Model
Settings
0x00204000
20
19
18
17
r
r
r
r
0
0
0
0
4
3
2
1
MINUTES
rw
rw
rw
rw
?
?
?
?
Settings
HOURS can be set to any value
between 0 and 23.
MINUTES can be set to any
value between 0 and 59.
Addr
16
r
0
0
rw
?
23-5