SSANGYONG Rexton Y200 Manual page 571

Hide thumbs Also See for Rexton Y200:
Table of Contents

Advertisement

Failure
Description
Code
Throttle position sensor
104
1 low voltage
Throttle position sensor
105
1 high voltage
Throttle position sensor
108
2 low voltage
Throttle position sensor
109
2 high voltage
Throttle actuator
learning control failure
116
Throttle valve return
119
spring failure
Throttle act uator failure
121
Different mass air flow
123
sensor signal with
throttle position sensor
Both throttle position
125
sensor failure
SSANGYONG Y200
Trouble Area
TPS 1 short circuit to ground
or open
TPS 1 short circuit to power
TPS 2 short circuit to ground
or open
TPS 2 short circuit to power
When actuat or adaption
fluctuation or not meet the
condition
When return spring
defective of actuator
When supply voltage of the
actuat or short circuit to
power
When shut down of out put
driver
When defective of both
potentiometers
M161 ENGINE CONTROLS 1F2-47
Maintenance Hint
Monitoring the actual values through
scan tool
Inspection the ECM pin 84, 85, 87, 112,
67, 68 about short circuit or open with
bad contact
Inspection the throttle valve actuator
Inspection the ECM
YAD1F420

Advertisement

Table of Contents
loading

Table of Contents