Failure
Description
Code
Acceleration pedal
position sensor signal
122
failure
Acceleration pedal
160
position 1 sensor low
voltage
Acceleration pedal
position sensor 1 high
161
voltage
Acceleration pedal
position sensor 2 low
162
voltage
Acceleration pedal
position sensor 2 high
163
voltage
Accelerator pedal
position sensor 1 not
plausible with
164
accelerator pedal
position sensor 2
Both setpoint
accelerator pedal
167
position sensor defective
Circuit Description
The ECM supplies a 5 or 2.5 volt reference signal and a ground to the APP sensor 1 or 2. The ECM calculates on
these signal lines. The APP sensor output changes as the accelerator pedal is moved. The output of the APP 1
and APP 2 sensor are low, about 0.4 ~ 0.7 volts and 0.2 ~ 0.35 volts respectively at the closed throttle position.
As pushing the accelerator pedal, the output increases so that the output voltages will be about 4.3 ~ 4.8 volts
and 2.1 ~ 2.4 volts individually when accelerating fully with the kick down, at Wide Open Throttle (WOT).
SSANGYONG Y200
Trouble Area
When malfunction of APP
sensor
APP 1 sensor short circuit to
ground or open
APP 1 sensor short circuit to
power
APP 2 sensor short circuit to
ground or open
APP 2 sensor short circuit to
power
When difference between
APP 1 sensor and APP 2
sensor
When defective of both APP
sensor
M161 ENGINE CONTROLS 1F2-59
Maintenance Hint
Monitoring the actual values through
scan tool
Inspection the ECM pin 31, 47, 32, 48,
59, 51 about short circuit or open with
bad contact
Inspection the APP sensor
Inspection the ECM