SSANGYONG Rexton Y200 Manual page 452

Hide thumbs Also See for Rexton Y200:
Table of Contents

Advertisement

Failure
Description
Code
Camshaft actuator short
circuit to battery
226
Camshaft actuator short
circuit to ground or
227
open
Camshaft Actuator Current Consumption Inspection
1. Run the engine to reach the coolant temperature above 70 ° C.
2. Increase the engine rpm up to 2000 rpm
3. Measure the current between the No. 1 and No. 2 pin of the camshaft actuator connector.
Specified Value
Notice: If the measured value is not within the specified value, check the cable.
SSANGYONG Y200
Trouble Area
When malfunction of cam
phasing control
1 ~1.5 A
M162 ENGINE CONTROLS 1F1-21
Maintenance Hint
Monitoring the actual operational status
through scan tool
Inspection the ECM pin 73 about short
circuit or open
Inspection the power source short circuit
or open to cam actuator
Inspection the magnet and hardware
Inspection the ECM
YAD1F150