Failure
Description
Code
Engine rpm output
32
circuit short circuit to
battery
Engine rpm output
33
circuit short circuit to
ground or open
SSANGYONG Y200

ENGINE RPM

Trouble Area
When short circuit to battery
When short circuit to ground
or open
M161 ENGINE CONTROLS 1F2-67
Maintenance Hint
Monitoring the actual rpm in cluster
Inspection the Engine Control Module
(ECM) pin 60 about short circuit or open
Inspection the cluster panel board circuit
Inspection the ECM