Failure
Description
Code
No ignition voltage
64
output
(No. 1 ignition coil)
No ignition voltage
output
65
(No. 2 ignition coil)
Circuit Description
The Electronic Ignition (EI) system uses a waste spark method of spark distribution. The Crankshaft Position
(CKP) sensor sends reference pulses to the ECM. The ECM then triggers the EI system ignition coils. Once the
ECM triggers the EI system ignition coils both of the connected spark plugs fire at the same time. One cylinder
is on its compression stroke at the same time that the other is on the exhaust stroke, resulting in lower energy
needed to fire the spark plug in the cylinder on its exhaust stroke.
This leaves the remainder of the high voltage to be used to fire the spark plug in the cylinder on its compression
stroke.
Since the CKP sensor is in a fixed position, timing adjustments are not possible or needed.
SSANGYONG Y200
Trouble Area
Malfunction of ignition circuit
Primary current values or
secondary short circuit
M161 ENGINE CONTROLS 1F2-11
Maintenance Hint
Inspection the ECM pin 71 and 72 about
short circuit or open with bad contact
Inspection the power source to ignition
coil
Inspection the ignition coil, high tension
cords etc.
Inspection the spark plug (wet, cracks,
wear, improper gap, burned electrodes,
heavy deposit)
Inspection the ECM
YAD1F0E0