5A-8 AUTOMATIC TRANSMISSION
Solenoid Operation during Gearshifts
Shift
To Initiate Shift
1-2
S1 OFF
S4 ON
1-3
S1 OFF
S2 OFF
S3 ON
S4 ON
1-4
S2 OFF
S3 ON
S4 ON
2-3
S2 OFF
S3 ON
S4 ON
3-4
S1 ON
S4 ON
4-3
S4 ON
4-2
S3 ON
4-1
S3 ON
S4 ON
3-2
S2 ON
S4 ON
3-1
S3 ON
S4 ON
2-1
S4 ON
Conv. Clutch
ON
S7 ON
OFF
Typical S5 Current Ramp
750mA to 600mA
850mA to 750mA
850mA to 750mA
700mA to 500mA
750mA to 600mA
750mA to 900mA
750mA to 950mA
600mA to 1000mA
600mA to 450mA @ 20 kph.
550mA to 400mA @ 60 kph.
800mA to 650mA @ 100 kph.
700mA to 950mA
800mA to 950mA
700mA to 400mA
600mA to 100mA
To Complete Shift
S4 OFF
S3 OFF
S4 OFF
S3 OFF
S4 OFF
S3 OFF
S4 OFF
S4 OFF
S1 OFF
S4 OFF
S1 OFF
S2 ON
S3 OFF
S2 ON
S3 OFF
S4 OFF
S4 OFF
S1 ON
S2 ON
S3 OFF
S4 OFF
S1 ON
S4 OFF
S7 OFF