Failure
See Page
code
44
1F1-62
45
1F1-62
54
1F1-41
56
1F1-23
57
1F1-23
58
1F1-17
59
1F1-78
60
1F1-78
62
1F1-61
64
1F1-11
65
1F1-11
66
1F1-11
67
1F1-13
68
1F1-25
71
1F1-29
72
1F1-37
73
1F1-37
74
1F1-37
75
1F1-37
76
1F1-37
77
1F1-38
78
1F1-38
79
1F1-38
80
1F1-72
81
1F1-73
82
1F1-72
83
1F1-72
84
1F1-72
85
1F1-72
86
1F1-72
87
1F1-72
89
1F1-72
93
1F1-73
96
1F1-73
97
1F1-73
98
1F1-73
99
1F1-73
100
1F1-73
101
1F1-73
102
1F1-73
SSANGYONG Y200
FAILURE CODES TABLE (Cont'd)
Cooling fan (HI) relay short circuit to power
Cooling fan (HI) relay short circuit to ground or open
Purge control circuit malfunction
No.1 knock sensor signal failure
No.2 knock sensor signal failure
Camshaft position sensor signal : No.1 cylinder synchronization failure
CAN communication failure : MSR data transmission not plausible
CAN communication failure : ASR data transmission not plausible
Clutch switch defective
No ignition voltage output (No.1 ignition coil)
No ignition voltage output (No.2 ignition coil)
No ignition voltage output (No.3 ignition coil)
Crankshaft position sensor adaptation failure
Random/Multiple Misfire
Starter signal recognition failure
No.1 injector short circuit to battery
No.1 injector short circuit to ground or open
No.2 injector short circuit to battery
No.2 injector short circuit to ground or open
No.3 injector short circuit to battery
No.3 injector short circuit to ground or open
No.4 injector short circuit to battery
No.4 injector short circuit to ground or open
Oxygen sensor high voltage
Bank 1 system short term fuel trim adaptation below lean threshold
Oxygen sensor no activity detected
Oxygen sensor not lean after overrun fuel shut -off
Oxygen sensor slow response
Oxygen sensor heater failure
Oxygen sensor heater short circuit to battery
Oxygen sensor heater short circuit to ground or open
Oxygen sensor low voltage
Bank 1 system short term fuel trim adaptation above rich threshold
Bank 1 system short term fuel trim at rich stop
Bank 1 system short term fuel trim at lean stop
Bank 1 system idle adaptation failure (above rich threshold)
Bank 1 system idle adaptation failure (below lean threshold)
Bank 1 system learning control failure (rich, low load)
Bank 1 system learning control failure (lean, low load)
Bank 1 system learning control failure (rich, high load)
M162 ENGINE CONTROLS 1F1-5