SSANGYONG Rexton Y200 Manual page 469

Hide thumbs Also See for Rexton Y200:
Table of Contents

Advertisement

Failure
Description
Code
Purge control valve
40
short circuit to battery
Purge control valve
41
short circuit to ground
or open
Purge control circuit
54
malfunction
SSANGYONG Y200
Trouble Area
When short circuit to power
source
When short circuit to ground
or open circuit or open with
bad contact
When malfunction of purge
control : not work vale
Test
1. Maintain the normal temperature and idling state by
2. Connect the ECM terminal No. 11 and No. 34 and
3. Connect the ECM terminal No. 34 and No.10 and
YAD1F0J0
4. Remove the line to canister and measure the
M162 ENGINE CONTROLS 1F1-41
Maintenance Hint
Inspection the ECM pin 34 about short
circuit or open with bad contact.
Inspection the source power of valve
Inspection the purge control solenoid
vale
Inspection the ECM
operating the engine.
check for normal operation through the output waves
using oscilloscope.
Notice: Test during purge control valve operation
after the minimum of 1 minute after the engine
turned on.
check for current consumption during the ignition
switch ON.
Specified Value
pressure with the vacuum pressure gauge.
Specified Value
Notice: Test while at normal temperature and at
idling state by operating the engine.
YAD1F310
0.3 ~ 0.5 A
> 500 mbar
(after approx. 1 min.)
purge control valve
operates at this time