1F1-68 M162 ENGINE CONTROLS
Failure
Description
Code
Engine rpm output
circuit short circuit to
32
battery
Engine rpm output
circuit short circuit to
33
ground or open
ENGINE RPM
Trouble Area
When short circuit to battery
When short circuit to ground
or open
Maintenance Hint
•
Inspection the cluster panel board circuit
•
Inspection the ECM
•
Monitoring the actual rpm in cluster
•
Inspection the Engine Control Module
(ECM) pin 60 about short circuit or open
YAD1F560