1F1-68 M162 ENGINE CONTROLS
Failure
Description
Code
Engine rpm output
circuit short circuit to
32
battery
Engine rpm output
circuit short circuit to
33
ground or open

ENGINE RPM

Trouble Area
When short circuit to battery
When short circuit to ground
or open
Maintenance Hint
Inspection the cluster panel board circuit
Inspection the ECM
Monitoring the actual rpm in cluster
Inspection the Engine Control Module
(ECM) pin 60 about short circuit or open