Tensioning Device Shock Absorber - SSANGYONG Rexton Y200 Manual

Hide thumbs Also See for Rexton Y200:
Table of Contents

Advertisement

TENSIONING DEVICE SHOCK ABSORBER

1 End Cover
2 Bolt.................... 40.5 - 9.5 N•m (29.9 - 6.5 lb-ft)
3 Tensioning Pulley
4 Bolt (M8 X 25) + Washer
.......................... 22.5 - 7.5 N•m (16.6 - 0.3 lb-ft)
SSANGYONG Y200
M161 ENGINE MECHANICAL 1B2-19
5 Tensioning Device
6 Bolt (M8 X 35) + Washer
.......................... 22.5 - 7.5 N•m (16.6 - 0.3 lb-ft)
7 Shock Absorber
Removal & Installation Procedure
1. Remove the end cover (1).
2. Remove the bolt (2) and remove the tensioning
pulley (3).
Installation Notice
Tightening Torque
3. Unscrew the bolts (4,6) and remove the shock ab-
sorber (7).
Installation Notice
Tightening Torque
YAD1B5T0
40.5 - 49.5 N•m
(29.9 - 36.5 lb-ft)
22.5 - 27.5 N•m
(16.6 - 20.3 lb-ft)

Advertisement

Table of Contents
loading