Abs Indicator Lamp Inoperative - SSANGYONG Rexton Y200 Manual

Hide thumbs Also See for Rexton Y200:
Table of Contents

Advertisement

4E-20 ABS AND TCS
Circuit Description
Battery voltage is supplied to the ABS lamp with the
ignition switch in the ON or START positions. The
warning lamp can be activated only by the ABS control
module internally supplying ground to terminal 20 or
by the shorting bar in the ABS module connector if the
connector in disconnected from the module.
Diagnosis
This procedure checks for a problem in the wiring, a
faulty ground, a voltage supply problem, a burned out
indicator lamp, or a contact problem in a connector.
Cause
A fuse has blown.
The indicator lamp has burned out.
There is a corroded or broken connector terminal.
There is a faulty ground connection.
There is a broken wire in a wring harness.
The EBCM is faulty.

ABS INDICATOR LAMP INOPERATIVE

Test Description
The number(s) below refer to step(s) on the diagnostic
table.
1. This test checks for any DTCs that may cause the
ABS indicator lamp to be inoperative.
2. This test verifies an inoperative lamp condition.
3. This test checks for voltage on the lamp circuit.
4. This begins a series of tests of the circuit from
the indicator lamp to the EBCM and ground.
19. This begins a series of tests of the voltage supply
circuits that power the indicator lamp.
YAD4E150