1F2-72 M161 ENGINE CONTROLS
Failure
Description
Code
Oxygen sensor high
voltage
80
Oxygen sensor low
voltage
89
Oxygen sensor no
82
activity detected
Oxygen sensor not lean
after overrun fuel
83
shut-off
Oxygen sensor slow
84
response
Oxygen sensor heater
85
failure
Oxygen sensor heater
short circuit to battery
86
Oxygen sensor heater
short circuit to ground
87
or open
Trouble Area
When recognition the output
that more than nominal
threshold, malfunction of
sensing voltage.
When recognition the output
that more than nominal
threshold, malfunction of
sensing voltage.
When recognition the output
that not active the sensor etc.
When recognition the output
that no lean signal after
overrun fuel shut-off
When slow response of sensor
signal
When recognition the heating
circuit
When recognition the heating
currents that more or less than
set values (less than 0.2 A or
more than 2 A)
When recognition the heating
voltages than less than set
values (less than 2 v)
Maintenance Hint
Monitoring the actual output signal
through scan tool
Inspection the ECM pin 16, 17 about
short circuit or open with bad contact
Inspection the oxygen sensor
Inspection the ECM
Monitoring the heating status through
scan tool
Inspection the ECM pin 9 about short
circuit or open with bad contact
Inspection the heating power source
Inspection the heating circuit of oxygen
sensor
Inspection the ECM