1 Bolt (M8 X 40, 3 pieces)
...................... 22.5 - 27.5 N•m (16.6 - 20.3 lb-ft)
2 Bolt (M8 X 70, 2 pieces)
...................... 22.5 - 27.5 N•m (16.6 - 20.3 lb-ft)
SSANGYONG Y200
M161 ENGINE MECHANICAL 1B2-13
GENERATOR
3 Bolt (M8 X 85, 1 piece)
...................... 22.5 - 27.5 N•m (16.6 - 20.3 lb-ft)
4 Generator Bracket
Removal & Installation Procedure
1. Disconnect the negative battery cable.
2. Remove the drive belt.
3. Remove the generator.
4. Unscrew the generator carrier bolts and remove
the carrier.
Installation Notice
Tightening Torque
Notice: Apply 3 Nm of torque when mounting the
bolt (1) ; apply 25 Nm of torque when mounting
the bolts (2), and (3) ; and then tighten the bolt (1)
with 25 Nm of torque.
5. Installation should follow the removal procedure
in the reverse order.
YAD1B5L0
70 N•m (52 lb-ft)