AUTOMATIC TRANSMISSION 5A-171
7. Depress the plug inward and remove the retaining
pin for each of the three valves.
Notice: Some of the valves and plugs are preloaded
by springs and may unexpectedly fall out of the
cover when the pins are removed.
8. Remove the four valves, plugs and springs.
KAA5A800
9. Remove the pump gears from the pump body.
10. Remove the lip seal from the front of the pump
body.
KAA5A810
Valve Body
1. Remove the manual valve detent spring and retain-
er plate using a T40 Torx bit.
2. Slide the manual valve out of the lower valve body.
Notice: Be aware that the manual valve will fall out
of the valve body.
3. Take note of the angular relationship of the
solenoid terminals to the valve body and remove
the solenoids 1, 2, 3, 4, 5, 6 and valve assemblies.
Notice: Take care that the bracket is not separated
from the solenoid.
KAA5A820
4. Place the valve body assembly on the bench with
the upper body uppermost.
5. Remove the 24 clamping screws with a No. 30
Torx bit. Separate the upper and lower valve
bodies by lifting the upper body and the separator
plate togeth-er.
6. Turn the upper body over and place it on the bench
with the separator plate uppermost.
KAA5A830