1B2-18 M161 ENGINE MECHANICAL
Preceding Work:
Removal of tensioning device shock absorber
1 Bolt (M8 x 75, 2 pieces) +
Washer ............ 22.5 - 27.5 N•m (16.6 - 0.3 lb-ft)
2 Bolt (M8 x 25, 1 pieces) +
Washer ............ 22.5 - 27.5 N•m (16.6 - 0.3 lb-ft)

TENSIONING DEVICE

3 Tensioning Device
4 Stud bolt
5 Tensioning Arm
Removal & Installation Procedure
1. Turn the stud bolt to counterclockwise.
2. Insert the pin (111 589 01 15 00) into the hole in
tensioning arm.
3. Unscrew the bolts (1, 2) and remove the tensioning
device.
Installation Notice
4. Installation should follow the removal procedure
in the reverse order.
YAD1B5S0
Tightening Torque
YAD1B5R0
22.5 - 27.5 N•m
(16.6 - 20.3 lb-ft)
SSANGYONG Y200