SSANGYONG Rexton Y200 Manual page 660

Hide thumbs Also See for Rexton Y200:
Table of Contents

Advertisement

1F3-36 DIESEL ENGINE CONTROLS
Tools Required
617 589 09 21 00 Rl Adapter
617 589 10 21 00 RI Sensor
667 589 00 21 00 TDC Pulse Generator
Commercial Tools
Digital Tester
Item
With Pluse Generator
Without Pulse Generator
Test Procedure
YAD1FBL0
YAD1FBM0
Bosch, MOT 001.03
Hartmann & Braun. EOMT3
Bosch, ETD 019.00
ALV, Diesel - Tester 875
1. Remove the screw plug (7) and seal (8) collect oil
in a suitable vessel.
2. Install the Rl sensor 617 589 10 21 00 into the
governor housing of injection pump (1).
3. Connect the digital tester and TDC pulse generator
667 589 00 21 00 according to connection diagram.
4. Run the engine at idle speed and check the Rl
value on the digital tester
RI valve
Notice: If out of standard, adjust the start of
delivery.
5. Stop the engine.
6. Remove the Rl sensor, digital tester and TDC pulse
generator.
7. Replace the seal and tighten the plug.
Installation Notice
Tightening Torque
8. Check engine oil level and adjust if necessary.
Tools
Sun, DIT 9000
ATDC 14° - 16°
30 N•m (22 lb-ft)
SSANGYONG Y200

Advertisement

Table of Contents
loading

Table of Contents