Failure
Description
Code
Bank 1 system short
term fuel trim
adaptation below lean
81
threshold
Bank 1 system short
term fuel trim
adaptation above rich
93
threshold
Bank 1 system short
term fuel trim at rich
96
stop
Bank 1 system short
term fuel trim at lean
97
stop
Bank 1 system idle
98
adaptationfailure
(above rich threshold)
Bank 1 system idle
adaptation failure
99
(below rich threshold)
Bank 1 system learning
100
control failure
(rich, low load)
Bank 1 system learning
101
control failure
(lean, low load)
Bank 1 system learning
102
control failure
(rich, high load)
Bank 1 system learning
103
control failure
(rich, low load)
SSANGYONG Y200
Trouble Area
When recognition the value
less than nominal control
threshold, it means that when
big deviation in control range
of adaptation values through
fuel and air mixture formation
When recognition the value
more than nominal control
threshold, it means that when
big deviation in control range
of adaptation values through
fuel and air mixture formation
When recognition the short
term fuel trim that more than
nominal threshold
When recognition the short
term fuel trim that less than
nominal threshold
When recognition the long
term fuel trim exceeds rich
threshold
When recognition the long
term fuel trim exceeds lean
threshold
When recognition the long
term fuel trim exceeds rich
threshold
When recognition the long
term fuel trim exceeds lean
threshold
When recognition the long
term fuel trim exceeds rich
threshold
When recognition the long
term fuel trim exceeds lean
threshold
M161 ENGINE CONTROLS 1F2-73
Maintenance Hint
Inspection the intake air leakage
Inspection the injection quantities with
injector block or leakage
Inspection the exhaust leakage
Inspection the ECM