3. Turn the ignition switch to "OFF" position.
4. Disconnect the ECT sensor connector.
5. Turn the ignition switch to "ON" position.
6. Measure the resistance between the ECT sensor terminal pin No. 1 and No. 4.
Temperature (°C)
20
80
100
Notice: Replace wiring and coolant temperature sensor if out of specified value.
SSANGYONG Y200
Specified Value (Ω Ω Ω Ω Ω )
2,500
322
185