Avaya S8700 Maintenance Manual page 2019

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

PNC-DUP (PNC Duplication)
g. A spontaneous PNC interchange took place in response to the retiring of
an alarm on the A-PNC associated with fault class FC_BFD. Use status
pnc to look at the state of health indexes for the PNCs, and investigate any
associated alarms. Adding 1 to the last two digits of the error code gives
the PN number of the port network that reported the retired alarm. (10203
points to port network 4.) List config port-network gives the cabinet
number associated with a port network.
h. A spontaneous PNC interchange took place in response to the retiring of
an alarm on the A-PNC associated with fault class FC_SNIL. Use status
pnc to look at the state of health indexes for the PNCs, and investigate any
associated alarms. The last two digits of the error code indicate the
fiber-link number (01-64) of the fiber that reported the retired alarm. List
fiber-link gives the location of the fiber.
i. A spontaneous PNC interchange took place in response to the retiring of
an alarm on the A-PNC associated with fault class FC_SNIHW. Use
status pnc to look at the state of health indexes for the PNCs, and
investigate any associated alarms. The last two digits of the error code
indicate the fiber-link number (01-64) of the fiber that reported the retired
alarm. List fiber-link gives the location of the fiber.
j. A spontaneous PNC interchange took place in response to the occurrence
of a major or minor alarm on the A-PNC associated with fault class FC_
EAL. This indicates that one or more Expansion Archangel Links are
down. Investigate any EXP-PN alarms. Adding 1 to the last two digits of
the error code gives the PN number of the port network that reported the
alarm. (11003 points to port network 4.) List config port-network gives
the cabinet number associated with a port network.
k. A spontaneous PNC interchange took place in response to the occurrence
of a major or minor alarm on the A-PNC associated with fault class FC_
INL. This indicates that one or more neighbor or indirect neighbor links
with an EI as an endpoint have experienced faults. Investigate any alarms
against EXP-PN and SN-CONF. Adding 1 to the last two digits of the error
code gives the PN number of the port network that reported the alarm.
(11103 points to port network 4.) List config port-network gives the
cabinet number associated with a port network.
l. A spontaneous PNC interchange took place in response to the occurrence
of a major or minor alarm on the A-PNC associated with fault class FC_
HW. This indicates that one or more neighbor or indirect neighbor links
with an EI as an endpoint have experienced faults. Investigate any alarms
against EXP-PN and SN-CONF. Adding 1 to the last two digits of the error
code gives the PN number of the port network that reported the alarm.
(11203 points to port network 4.) List config port-network gives the
cabinet number associated with a port network.
555-233-143
Issue 1 May 2002
8-1297

Advertisement

Table of Contents
loading

Table of Contents