PNC-DUP (PNC Duplication)
In any multifault situation, rely on status pnc to determine which is the active
PNC.
PNC duplication informs Timing Synchronization maintenance when a PNC
interchange has been completed and indicates which PNC is active. This will
cause Synchronization to audit and insure that the primary source for
synchronization of Tone-Clocks in each PN is supplied by a path associated with
the active PNC.
Antithrashing and PNC Interchanges
Following a spontaneous PNC interchange, subsequent PNC interchanges are
prevented for 5 minutes. This condition is indicated by a yes in the
Interchange Disabled? field of the Status PNC form. After 5 minutes, the
antithrashing, timer expires, interchange decisions are re-enabled, and the field
displays no.
NOTE:
Should a catastrophic failure occur on the active PNC during the period
when "Interchange Disabled?" is set to "yes" there will be no spontaneous
PNC interchange.
Demand PNC interchanges also invoke anti-thrashing, but only for a period of 30
seconds. During antithrashing mode, demand interchanges are also prevented
unless the override option is specified. Use of this option will cause a service
disruption.
Repairs on the Standby PNC Components
!
CAUTION:
If there is a TDM-CLK alarm, system timing may be routed through part of
the standby PNC, and circuit switched data may be affected by the following
repair procedures. This can happen, for example, when a slave tone/clock
circuit pack experiences a loss of signal and switches to receive timing from
the standby EI. In this case TDM-CLK 2305 error will be logged, and the
clock problem should be addressed first, if possible.
To repair PNC components in a duplicated PNC proceed as follows:
1. Most repairs will involve fixing a single fault on the standby PNC. Use set
pnc lock or busy-out pnc to prevent an interchange into the PNC being
repaired.
2. If a faulty component exists on the currently active PNC, the standby PNC
is more severely faulted. Normally the standby PNC will be fully repaired
first since it is the most severely impaired. To repair the active PNC,
request an interchange via the reset pnc interchange override-and-lock
command. The override-and-lock option ensures that no subsequent
555-233-143
Issue 1 May 2002
8-1293