Maintenance-Object Repair Procedures
Table 8-524. Test #5 Battery and Battery Charger Query Test — Continued
Error
Test
Code
Result
Description / Recommendation
2. If after 30 hours the battery is still in the high charge rate, an alarm will be
6
FAIL
This indicates that error codes 2 and 4 have occurred. Refer to these
descriptions. Also, refer to this test's description for error code 14.
8-1308
Issue 1 May 2002
raised. Display the Error Log with the display errors command and
select the category "environs" to display only environment-related errors.
Look for POWER errors of type 257. The first occurrence of this error
indicates the time when the battery started charging. Use this time as the
starting point to determine whether the battery has been charging for 30
hours. If so, then replace the battery and battery charger.
!
CAUTION:
Read the section,
''Replacing the Battery and Battery Charger
(J58890CE)''
before proceeding. 3) Rerun the test. If the test
still fails, then the PN's MAINT (Maintenance) circuit pack could
be reporting this condition incorrectly. There are failures that
can occur on the PN's Maintenance circuit pack that will not be
detected by their respective maintenance, but which will cause
many, if not every, environment test to fail. If many environment
tests are failing, the suspect circuit pack, depending on the
system configuration, should be replaced and the test rerun.
Resolve every alarm on these MOs, and rerun the test.