POWER
Note:
a. Check to see if the battery charger is connected. If the cabinet is powered
by a UPS, there is no battery backup, and this error can be ignored.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. For example, by clearing error codes associated with the
Battery and Battery Charger Query test (#5), you may also clear errors generated
from other tests in the testing sequence.
Table 8-523. System Technician-Demanded Tests: POWER
Order of Investigation
Battery and Battery Charger Query test (#5)
AC Power Query test (#78) (a)
Power Unit Query test (carrier E) (#127) (b)
Power Unit Query test (carrier D) (#127) (b)
Power Unit Query test (carrier A) (#127) (b)
Power Unit Query test (carrier B) (#127) (b)
Power Unit Query test (carrier C) (#127) (b)
Emergency Transfer Query test (#124) (c)
Cabinet Sensors Query test (#122) (d)
External Alarm Lead Query test (#120) (e)
Analog Ring Generator Initialization test (#117) (f)
Analog Ring Generator Query test (#118) (f)
1.
D = Destructive, ND = Nondestructive
Notes:
a. See
''AC-POWER'' on page 8-4
b. See
''CARR-POW (Carrier Power Supply)'' on page 8-393
this test.
c. See EMG-XFER (Emergency Transfer) for a description of this test.
d. See
''CABINET (Cabinet Sensors)'' on page 8-383
test.
e. See EXT-DEV (External Alarm) for a description of this test.
f. See
''RING-GEN'' on page 8-1357
555-233-143
Short Test
Long Test
Sequence
Sequence
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
for a description of this test.
for a description of
for a description of this
for a description of this test.
Issue 1 May 2002
1
D/ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
8-1305

Advertisement

Table of Contents
loading

Table of Contents