Avaya S8700 Maintenance Manual page 2026

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
5. Check the battery dates and the preventive maintenance log. Replace the
batteries if they are more than 2.5 years old.
6. If no defective batteries are found, replace the entire charger.
7. Close the cover and secure it with the screw.
8. Reconnect the cord and move the power switch to ON.
Replacing the Battery Assembly (J58890CH)
The batteries are replaced as an entire assembly.
1. Check the battery voltages at the test points on the BIU (Battery Interface
Unit).
2. Remove the BIU from the power distribution unit.
3. Disconnect the battery plug from the power distribution unit (J20).
4. Remove the battery assembly from the rear of the cabinet.
5. Install the new battery assembly in the reverse order.
6. Plug the BIU back into the power distribution unit.
Error Log Entries and Test to Clear Values
Table 8-522. Battery and Battery Charger Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
1
Any
Battery and Battery Charger
Query test (#5) (error code 8)
257
Any
Battery and Battery Charger
Query test (#5) (error code 4)
769
Any
Battery and Battery Charger
Query test (#5) (error code 2)
3840
1005
Associated Battery and
(a)
or
Battery Charger Query test
1028
(#5)
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
8-1304
Issue 1 May 2002
NOTE:
If any defective batteries are found, replace all of them. Batteries are
ordered in sets of three and should be replaced as such.
Alarm
On/Off
Level
Board
Test to Clear Value
Any
Any
test environment UU sh r 1
MINO
ON
test environment UU s r 1
R
MINO
ON
test environment UU s r 1
R
MINO
ON
test environment UU s r 1
R
test environment UU s r 1
555-233-143

Advertisement

Table of Contents
loading

Table of Contents