Alarm Oam Error-Frame-Period - 3Com S7906E Command Reference Manual

6300 series
Hide thumbs Also See for S7906E:
Table of Contents

Advertisement

Examples
# Enable the error symbol period alarm on ONU 3/0/1:1.
<Sysname> system-view
[Sysname] interface onu 3/0/1:1
[Sysname-Onu3/0/1:1] alarm oam error-symbol-period enable

alarm oam error-frame-period

Syntax
alarm oam error-frame-period { window window | threshold threshold } *
undo alarm oam error-frame-period { window | threshold } *
View
OLT port view, ONU port view, FTTH view
Default Level
2: System level
Parameters
window window: Specifies the window size, in the range 0 to 4294967295 (2
the window size is 1 second.
threshold threshold: Specifies the alarm threshold, in the range 1 to 4294967295 (2
default, the threshold is 20 frames.
Description
Use the alarm oam error-frame-period command to configure the corresponding window size and
alarm threshold.
Use the undo alarm oam error-frame-period command to restore the default window size and alarm
threshold.
The system generates an error frame period alarm when the number of error frames in a specific time
period (that is, the window size) exceeds the corresponding predefined threshold.
Related commands: alarm oam error-frame-period enable.
When the alarm threshold is set to 0, large amount of alarms are generated immediately. Since
alarm events are carried in the OAM packets, large amount of OAM packets are generated. In this
case, OAM packets may be lost.
The commands here take effect only for OAM 2.0 and above.
Examples
# Set the window size and alarm threshold for error frame period to 2 seconds and 30 frames on ONU