[Sysname] interface tunnel 2/0/3
[Sysname-Tunnel2/0/3]
service-loopback-group
Syntax
service-loopback-group number
undo service-loopback-group
View
Tunnel interface view
Default Level
2: System level
Parameters
number: Service loopback group ID, in the range of 1 to 1024.
Description
Use the service-loopback-group command to reference a service loopback group on the tunnel
interface.
Use the undo service-loopback-group command to remove the referenced service loopback group
from the tunnel interface.
By default, no service loopback group is referenced on a tunnel interface.
The service loopback group to be referenced must have been configured and have the service type set
to tunnel in system view.
One tunnel interface can reference only one service loopback group.
Related commands: service-loopback group in Service Loopback Group Commands in the Access
Volume.
Examples
# Create service loopback group 1 of tunnel type.
<Sysname> system-view
[Sysname] service-loopback group 1 type tunnel
# Add a Layer 2 GigabitEthernet interface to service loopback group 1.
[Sysname] interface gigabitethernet 1/0/1
[Sysname-GigabitEthernet1/0/1] stp disable
[Sysname-GigabitEthernet1/0/1] port service-loopback group 1
[Sysname-GigabitEthernet1/0/1] quit
# Reference service loopback group 1 on interface tunnel 2.
[Sysname] interface tunnel 2/0/2
[Sysname-Tunnel2/0/2] service-loopback-group 1
1-8
Need help?
Do you have a question about the S7906E and is the answer not in the manual?
Questions and answers