Alarm Oam Error-Frame-Period Enable; Alarm Oam Error-Frame - 3Com S7906E Command Reference Manual

6300 series
Hide thumbs Also See for S7906E:
Table of Contents

Advertisement

<Sysname> system-view
[Sysname] interface onu 1/0/1:1
[Sysname-Onu1/0/1:1] alarm oam error-frame-period window 2 threshold 30

alarm oam error-frame-period enable

Syntax
alarm oam error-frame-period enable
undo alarm oam error-frame-period enable
View
OLT port view, ONU port view, FTTH view
Default Level
2: System level
Parameters
None
Description
Use the alarm oam error-frame-period enable command to enable the error frame period alarm.
Use the undo alarm oam error-frame-period enable command to disable the error frame period
alarm.
By default, the error frame period alarm is enabled.
The commands here take effect only for OAM 2.0 and above.
Examples
# Enable the error frame period alarm for the ONU corresponding to ONU 3/0/1:1.
<Sysname> system-view
[Sysname] interface onu 3/0/1:1
[Sysname-Onu3/0/1:1] alarm oam error-frame-period enable

alarm oam error-frame

Syntax
alarm oam error-frame { window window | threshold threshold } *
undo alarm oam error-frame { window | threshold } *
View
OLT port view, ONU port view, FTTH view
3-11

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

S7910eS7906e-vS7903eS7903e-sS7902e

Table of Contents