<Sysname> system-view
[Sysname] interface onu 1/0/1:1
[Sysname-Onu1/0/1:1] alarm oam error-frame-period window 2 threshold 30
alarm oam error-frame-period enable
Syntax
alarm oam error-frame-period enable
undo alarm oam error-frame-period enable
View
OLT port view, ONU port view, FTTH view
Default Level
2: System level
Parameters
None
Description
Use the alarm oam error-frame-period enable command to enable the error frame period alarm.
Use the undo alarm oam error-frame-period enable command to disable the error frame period
alarm.
By default, the error frame period alarm is enabled.
The commands here take effect only for OAM 2.0 and above.
Examples
# Enable the error frame period alarm for the ONU corresponding to ONU 3/0/1:1.
<Sysname> system-view
[Sysname] interface onu 3/0/1:1
[Sysname-Onu3/0/1:1] alarm oam error-frame-period enable
alarm oam error-frame
Syntax
alarm oam error-frame { window window | threshold threshold } *
undo alarm oam error-frame { window | threshold } *
View
OLT port view, ONU port view, FTTH view
3-11