Parameters
uni-number: UNI number, in the range 1 to the number of UNI ports of the current ONU. The number of
UNIs can be up to 80.
both: Mirrors both inbound and outbound packets on the port.
inbound: Mirrors only inbound packets on the port.
outbound: Mirrors only outbound packets on the port.
Description
Use the uni mirroring-port command to configure a UNI as the mirroring port.
Use the undo uni mirroring-port command to cancel the configuration of a UNI as the mirroring port.
Examples
# Mirror the outbound packets on UNI 1.
<Sysname> system-view
[Sysname] interface onu 2/0/1:1
[Sysname-Onu2/0/1:1] uni 1 mirroring-port outbound
uni monitor-port
Syntax
uni uni-number monitor-port
undo uni uni-number monitor-port
View
ONU port view
Default Level
2: System level
Parameters
uni-number: UNI number, in the range 1 to the number of UNI ports of the current ONU. The number of
UNIs can be up to 80.
Description
Use the uni monitor-port command to configure a UNI as the monitor port.
Use the undo uni monitor-port command to cancel the configuration of a UNI as the monitor port.
Examples
# Mirror the outbound packets on UNI 1 to UNI 2.
<Sysname> system-view
[Sysname] interface onu 2/0/1:1
[Sysname-Onu2/0/1:1] uni 1 mirroring-port outbound
[Sysname-Onu2/0/1:1] uni 2 monitor-port