Timer - 3Com S7906E Command Reference Manual

6300 series
Hide thumbs Also See for S7906E:
Table of Contents

Advertisement

RRPP configured with ring groups cannot interoperate with RRPP that does not support ring group
configuration.
Related commands: domain ring, display rrpp ring-group.
Examples
# Create ring group 1 and enter its view.
<Sysname> system-view
[Sysname] rrpp ring-group 1
[Sysname-rrpp-ring-group1]

timer

Syntax
timer hello-timer hello-value fail-timer fail-value
undo timer
View
RRPP domain view
Default Level
2: System level
Parameters
hello-value: Hello timer value, in the range 1 to 10 seconds.
fail-value: Fail timer value, in the range 3 to 30 seconds.
Description
Use the timer command to specify the value of the timers of the RRPP domain.
Use the undo timer command to restore it to the default value.
By default, the Hello timer value is 1 second and the Fail timer value is 3 seconds.
Note that the Fail timer value must be greater than or equal to three times of the Hello timer value.
Examples
# Set the Hello timer value to 2 seconds and the Fail timer value to 7 seconds.
<Sysname> system-view
[Sysname] rrpp domain 1
[Sysname-rrpp-domain1] timer hello-timer 2 fail-timer 7
1-17

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S7906E and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

S7910eS7906e-vS7903eS7903e-sS7902e

Table of Contents