timer monitor
Syntax
timer monitor seconds
undo timer monitor
View
FTTH view
Default Level
3: Manage level
Parameters
seconds: Alarm monitor period, ranging from 1 to 3600 (in seconds). The system default is 80 seconds.
Description
Use the timer monitor command to configure the alarm monitor period of the system.
Use the undo timer monitor command to restore the default monitor period.
Examples
# Configure the alarm monitor period of the EPON system to 100 seconds.
<Sysname> system-view
[Sysname] ftth
[Sysname-ftth] timer monitor 100
timer sample
Syntax
timer sample seconds
undo timer sample
View
FTTH view
Default Level
3: Manage level
Parameters
seconds: Sampling interval (in seconds). It is in the range 1 to 3600 and defaults to 4.
Description
Use the timer sample command to set the sampling interval for the system.
Use the undo timer sample command to restore the default sampling interval for the system.
Examples
# Set the sampling interval of the EPON system to 10 seconds.